SPECIFICATIONS – REGULAR

Product Features:

  • LED indication for timing in progress
  • Front protective cover for safety.
  • Timer and base available for Track(except H3D1).
  • Large transparent knob with lock is provided for precise time setting and protect from unintentional change of time setting.
  • H1DA-X : Accepts any voltage from 12V AC/DC to 240V AC / 220V DC as signal between command contacts for timing initiation.
  • H1D1-X, H3D1: Multifunction-On-Delay / Interval / Equal Cyclic-On / Equal Cyclic-Off programmable.
ModelH1DT-10H1DT-30H1DT-60H4DT-10H4DT-30H4DT-60
FunctionOn-Delay
Rated supply voltage24V to 240V AC, 24V DC to 220V DC
Operating voltage range-10% to +10% of rated voltage
Rated frequency50Hz ± 5%
Power consumptionAC approx.3VA / 1W, DC approx. 2W
Allowable ripple (for DC supply)3% maximum
Control relay output2 c/o rated for 5A@250V AC / 28V DC, resistive load
Time range1Sec to 10Secs3Secs to 30Secs6Secs to 60Secs1Sec to 10Secs3Secs to 30Secs6Secs to 60Secs
Setting accuracy± 10% max. w.r.t full scale ± 100msec
Repeat accuracy± 1% max. ± 100msec
Recovery time100msec minimum
Variation due to voltage change± 2% max ± 100msec
Variation due to temp. change± 5% max ± 100msec
Variation due to frequency change± 2% max ± 100msec
Ambient temperatureOperation: -100C to +550C, Storage: -250C to +800C
HumidityMax. 85% RH @ 400C
Service life (under no load)106 operations minimum
Electrical life (under full load)105 operations minimum
Rated frequency of operation1800 ± 5% operations per hour maximum
Insulation resistance> 100M ohms @ 500V DC
Di-electrical strength1. 1.5KV AC (rms), 50Hz for 1minute. (Between input terminals and enclosure).

2. 1.5KV AC (rms), 50Hz for 1minute. (Between relay contact terminals and enclosure).

3. 1.5KV AC (rms), 50Hz for 1minute. (Between input terminals and relay contact terminals).

4. 1.0KV AC (rms), 50Hz for 10-30sec. Between non-continuous contacts of the relay)

1. 2.5KV AC, 50Hz for 1minute. (Between current carrying and non-current carrying parts).

2. 1.5KV AC, 50Hz for 1minute. (Between contacts and control circuit).

3. 1.0KV AC, 50Hz for 1minute. (Between non-continuous contacts of the relay).

Electrical connection11 pin plug-in type8 pin plug-in type
Dimension (over-all)48 x 48 x 94mm (W x H x D)
Enclosure (series)H1D series
ApprovalCSA (FILE NO : LR 105610)N.A
Panel CutoutN.A45mm x 45mm

Connections:

Dimensions:

Timing Diagram:

Accessories:

  • Protective Cover: The protective cover shields the front panel, particularly the timer setting section from dust and dirt. It also prevents the set value from being altered due to accidental contact with time setting knob.
  • Side anchor for panel mounting.
  • Knob lock / Screw driver.
  • Base

 

Hints on correct use:

  • Properly insert the timer pins into the base slots taking into consideration the wedge in the timer and notch in the base.
  • While selecting the time range ensure proper positioning of SEC / MIN within the window cutout.
  • Ensure proper alignment of full range with respect to markings on the scale.

Caution:

  • • Do not change the time range & set time while the timer is in operation.
  • • Switch off the power while changing the time range & set time.
  • • Application of voltage other than the specified one, will permanently damage the timer.
  • • Use 2.5mmU-type lugs with sleeve for connections and wiring .
  • NOTE : User should not apply external voltage to the terminals that are designated as potential free(Zero/No Volt).