1 winpin up casino gamepinupaviator bonus game1 win casino
  • LEADING PROVIDER

    OF INDUSTRIAL SOLUTIONS

  • PRODUCT BEST RATE
  • NO. 1 EASTERN INDIA
  • LEADING PROVIDER

    OF INDUSTRIAL SOLUTIONS

  • PRODUCT BEST RATE
  • NO. 1 EASTERN INDIA

SPECIFICATIONS – REGULAR

Product Features:

  • LED indication for timing in progress
  • Front protective cover for safety.
  • Timer and base available for Track(except H3D1).
  • Large transparent knob with lock is provided for precise time setting and protect from unintentional change of time setting.
  • H1DA-X : Accepts any voltage from 12V AC/DC to 240V AC / 220V DC as signal between command contacts for timing initiation.
  • H1D1-X, H3D1: Multifunction-On-Delay / Interval / Equal Cyclic-On / Equal Cyclic-Off programmable.
ModelH1D1-XH1DA-XH3D1
FunctionOn-Delay / Interval / Cyclic On-Off / Cyclic Off-OnSignal Off-DelayOn-Delay / Interval / Cyclic On-Off / Cyclic Off-On
Rated supply voltage24V to 240V AC, 24V to 220V DC
Operating voltage range-10% to +10% of rated voltage
Rated frequency50Hz ± 5%
Power consumptionAC approx.3VA / 1W, DC approx. 2W  AC approx.5VA / 1W, DC approx. 3WAC approx.3VA / 1W, DC approx. 2W
Allowable ripple (for DC supply)3% maximum
Control relay output2 c/o rated for 5A@250V AC / 28V DC, resistive load
Start signalN.A12V AC to 240V AC (50Hz), 12V DC to 220V DC for 150msec minimumN.A
Time range0.3secs to 60mins.0.6secs to 60mins.0.3secs to 60mins.
Range selection3S, 6S, 30S, 60S, 3M, 6M, 30M, 60M6S, 60S, 6M,  60M3S, 6S, 30S, 60S, 3M, 6M, 30M, 60M
Setting accuracy± 10% max. w.r.t full scale ± 100msec
Repeat accuracy± 1% max. ± 100msec
Recovery time100msec minimum
Variation due to voltage change± 2% max ± 100msec
Variation due to temp. change± 5% max ± 100msec
Variation due to frequency change± 2% max ± 100msec
Ambient temperatureOperation: -100C to +550C, Storage: -250C to +800C
HumidityMax. 85% RH @ 400C
Service life (under no load)106 operations minimum
Electrical life (under full load)105 operations minimum
Rated frequency of operation1800 ± 5% operations per hour maximum
Insulation resistance>100M ohms @ 500V DC
Di-electrical strength1. 1.5KV AC (rms), 50Hz for 1minute. (Between input terminals and enclosure).

2. 1.5KV AC (rms), 50Hz for 1minute. (Between relay contact terminals and enclosure).

3. 1.5KV AC (rms), 50Hz for 1minute. (Between input terminals and relay contact terminals).

4. 1.0KV AC (rms), 50Hz for 10-30sec. Between non-continuous contacts of the relay).

1. 2.5KV AC, 50Hz for 1minute. (Between current carrying and non-current carrying parts).

2. 1.5KV AC, 50Hz for 1minute. (Between contacts and control circuit).

3. 1.0KV AC, 50Hz for 1minute. (Between non-continuous contacts of the relay).

Electrical connection11 pin plug-in typeScrew type terminals with self lifting clamps
Dimension (over-all)48 x 48 x 94mm (W x H x D)
Enclosure (series)H1D series
ApprovalCSA (FILE NO : LR 105610)N.A

Connections:

Dimensions:

Timing Diagram:

Accessories:

One H3D1
One Instruction manual

Hints on correct use:

  • Properly insert the timer pins into the base slots taking into consideration the wedge in the timer and notch in the base.
  • While selecting the time range ensure proper positioning of SEC / MIN within the window cutout.
  • Ensure proper alignment of full range with respect to markings on the scale.

Caution:

  • Apply appropriate personal protective equipment(PPE) and follow safety work practices
  • Only qualified electrical workers should install this equipment. Such work should be performed only after reading this entire set of instructions.
  • If the equipment is not used in the manner specified by the manufacturer, the protection provided by the equipment may be impaired.
  • NEVER work alone.
  • The successful operation of this equipment depends upon proper handling, installation and operation. Neglecting fundamental installation requirements may lead to personal injury as well as damage to electrical equipment or other property
  • NEVER bypass external fusing.
  • Failure to follow these instructions will result in death or serious injury.
  • EAPL is not responsible for any consequential damages arising out of use of our products, though the technology is cautiously chosen and implemented like any other well designed good electric device