SPECIFICATION

Product Features:

  • Din Sized enclosure for panel mounting.
  • Digital dual display for set value and process value.
  • FUNCTION (programmable): ON DELAY / INTERVAL /CYCLIC ADJUSTABLE.
  • TYPE OF START SIGNAL (programable) : NO START / PULSE / CONTINUOUS.
  • One of the relay c/o can be configured as INSTANT or DELAYED.
  • Program lock is provided for function, relay configuration, type of start signal and range selected.
  • RESET cum START facility can be achieved either through front buttons Or Rear terminals
  • HOLD/RESTART facility during power failure conditions.
  • Internal Resettable fuse for protection of device against voltage fluctuations(N.A. for H3PT-MU). Digital display will blink whenever voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal
ModelH3PT-MUC3PT-MUE3PT-MU
FunctionOn-Delay / Interval / Cyclic (up counting)
Rated supply voltage85V to 270V AC, 85V DC to 270V DC
Rated frequency50 / 60Hz  ±5% for AC supply only
Power consumptionAC approx.10VA / DC approx 5WAC approx. 15VA /3W
Time Range0.10secs to 99hrs 59min.
Display4 digit 7 segment LED 0.28″4 digit 7 segment LED 0.56″
Range selectionRange     Minimum          Maximum

S/S         0.1s          59.90s

M/S        1s           59.59Min

H/M       1m           99.59Hrs

Setting accuracy± 1%  ± 50msec
Repeat accuracy± 0.05% max. ± 50msec
Recovery time2sec minimum
Resetting timeN.A
Variation due to voltage change± 1% max ± 100msec
Variation due to temp. change± 2% max ± 100msec
Variation due to frequency change± 1% max ± 100msec
Ambient temperatureOperationc -100C to +550C, Storagec -250C to +800C
HumidityMax. 85% RH @ 400C
Service life (under no load)106 operation minimum
Electrical life (under full load)105 operation minimum
Rated frequency of operation1800 ± 5% operations per hour maximum
Insulation resistance> 100M ohms @ 500V DC
Di-electrical strength1)  2.5KV AC, 50Hz for 1minute. (Between current carrying and non-current carrying parts).

2)  1.5KV AC, 50Hz for 1minute. (Between contacts and control circuit).

3)  750V AC, 50Hz for 1minute. (Between non-continuous contacts of the relay).

Control Output
Relay1*1C/O rated for 5A @ 250VAC/28VDC resistive loadInstant : 1C/O rated for 5A @ 250V AC/28V DC resistive load
Relay2**1C/O rated for 5A @ 250VAC/28VDC resistive loadDelay : 2C/O rated for 5A @ 250VAC/28VDC resistive load
Start & Reset signal250mSec minimum(Potential free)
Electrical connectionScrew type terminals with self lifting clamps
Dimension (over-all)48 x 48 x 115mm (W x H x D)72 x 72 x 128.5mm (W x H x D)96 x 96 x 117mm (W x H x D)
Enclosure (series)H1D series (long box)C1D seriesN.A
Panel cutoutN.A68mm sqN.A

Connections:

Dimensions:

Accessories:

  • Front  Protective Cover:  The front  protective cover shields the front panel from dust and dirt and water drip. It also prevents the set value from being altered due to accidental contact with tact switches.
  • Back Protective Cover: Back protective cover (H3PT-MU, C3PT-MU) protects the user tact switches.

Caution:

  • Do not change the time range & set time while the timer is in operation
  • Application of voltage other than the specified one, will permanently damage the timer.
  • Use 2.5mmU-type lugs with sleeve for connections and wiring .
  • NOTE : User should not apply external voltage to the terminals that are designated as potential free(Zero/No Volt).
  • Internal Resettable fuse for protection of device against voltage fluctuations. Digital display will blink whenever the voltage exceeds specified voltage range. Switch off the unit for sometime & then switch on when voltage returns to normal.