SPECIFICATIONS – REGULAR

Product Features:

  • Din sized enclosure for Track (Din rail) / Screw mounting.
  • Front terminal protective cover for safety.
  • LED indication for timing in progress.
  • A1DA :External (zero volt / potential free) command contact for timing initiation.
ModelA1D1A1D1-XA1D1X(60M)A1DE-XA1DN-XA1DCS-X
FunctionOn-Delay TimerOn-Delay  TimerOn-Delay  TimerInterval TimerAux. Relay TimerEqual Off-On Cyclic
Rated supply voltage240V AC24V to 240V AC, 24V to 220V DC
Operating voltage range-20% to +10% of rated voltage-10% to +10% of rated voltage
Rated frequency50Hz ±5%50 / 60Hz ±5%
Allowable ripple (for DC supply only)N.A3% maximum
Power consumptionAC approx.10VA / 2WAC approx. 5VA / 1W, DC approx. 3WAC approx. 3VA / 1W, DC approx. 2WAC approx. 5VA / 1W, DC approx. 3W
Control relay output2C/O rated for 5A @ 250VAC/28VDC resistive load2 c/o rated for 5A@250V AC /

28V DC, resistive load

Time range0.3Sec – 30Min0.3Sec – 30Min0.6Sec – 60Min0.3Sec – 30Min20mSec max0.6Sec – 60Min
Range selection3S, 30S, 3M, 30M3S, 30S, 3M, 30M6S, 60S, 6M, 60M3S, 30S, 3M, 30MN.A6S, 60S, 6M, 60M
Setting accuracy±10% max. w.r.t full scale ±100mSecN.A±10% max. w.r.t full scale ±100mSec
Repeat accuracy±1% max.± 100mSecN.A±1% max.± 100mSec
Recovery time100mSec minimum
Variation due to voltage change±2% max.±100mSecN.A±2% max.±100mSec
Variation due to temperature change±5% max.±100mSecN.A±5% max.±100mSec
Variation due to frequency change±2% max.±100mSecN.A±2% max.±100mSec
Ambient temperatureOperation : -10°C to +55°C, Storage : -25°C to +80°C
HumidityMax. 85% RH@40°C
Service life (under no load)106 operations minimum
Electrical life (under full load)105  operations minimum
Rated frequency of operation1800±5% operations per hour maximum
Insulation resistance>100M ohms@500V DC
Dielectric strength1. 1.5KV AC(rms), 50Hz for 1min (Between INPUT terminals and enclosure)

2. 1.5KV AC(rms), 50Hz for 1min (Between relay contact terminals and enclosure)

3. 1.5KV AC(rms), 50Hz for 1min (Between INPUT terminals & relay contact terminals)

4. 1.0KV AC(rms), 50Hz for 10-30sec(Between non-continuous contacts of the relay)

1. 1.5KV AC(rms), 50Hz for 1min (Between INPUT terminals and enclosure)

2. 1.5KV AC(rms), 50Hz for 1min (Between relay contact terminals and enclosure)

3. 1.5KV AC(rms), 50Hz for 1min (Between INPUT terminals & relay contact terminals)

4. 1.0KV AC(rms), 50Hz for 10 to 30sec (Between non continuous contacts of the relay)

Electrical connectionScrew type terminals with self lifting clamps
Dimension22.5 x 75 x 102mm (W x H x D)
Enclosure (series)A1D series
ApprovalCSA (FILE NO : LR 105610)

Connections:

Dimensions:

Timing Diagram:

Accessories:

Protective Cover: The protective cover shields the front panel, particularly the timer setting section from dust and dirt. It also prevents the set value from being altered due to accidental contact with time setting knob

Hints on correct use:

Change the positions of range selector slide switches on the left hand side of the timer to set the range required & then rotate the pot to set the desired time setting with the flat blade screw driver.

Caution:

  • Apply appropriate personal protective equipment(PPE) and follow safety work practices
  • Only qualified electrical workers should install this equipment. Such work should be performed only after reading this entire set of instructions.
  • If the equipment is not used in the manner specified by the manufacturer, the protection provided by the equipment may be impaired.
  • NEVER work alone.
  • NEVER bypass external fusing.
  • The successful operation of this equipment depends upon proper handling, installation and operation. Neglecting fundamental installation requirements may lead to personal injury as well as damage to electrical equipment or other property.
  • Failure to follow these instructions will result in death or serious injury.
  • EAPL is not responsible for any consequential damages arising out of use of our products, though the technology is cautiously chosen and implemented like any other well designed good electric device