SPECIFICATION

Product Features:

  • Switches On and Off 4 times in a day with respect to real time.
  • LED indication for relay status, LCD display for real time clock.
  • User friendly programming with manual over ride facility.
  • Clock hour and Clock minute buttons can be enabled by shorting terminals to program RTC.
  • For TS-203, TS-203B : Use (1.5Vx2)AA size Batteries
ModelTS-203TS-203B
FunctionDigital Daily Time Switch With 4 Programs
Number of Programs4 Programs per day.
Rated supply Voltage240V AC
Operating voltage range-20% to +10% of the rated voltage
Rated Frequency50Hz ± 5%
Power consumptionFrom Mains : AC Approx. 12.5VA ( 2.5W)
Battery backup1 year Min
Control output1 c/o rated for 16A @ 250V AC/28VDC resistive load
Time RangeON TIME : 00H 00M to 23H 59M DURATION : 00H 01M to 23H 59M
Display0.39″ LCD
Switching accuracy± 2Sec max
Recovery Time100mSec minimum
Variation due to voltage change± 2% Sec max
Variation due to temperature change± 2% Sec max
Variation due to frequency change± 2% Sec max
Ambient temperature00C to +500C(with no icing)
HumidityMAX 85% RH @ 400C
Service life (under no load)106 operations minimum
Electrical life (under full load) 105 operations minimum105 operations minimum
Insulation resistance>100M ohms @ 500V DC
Dielectric strengtha) 2.5KV AC, 50Hz for 1 minute. ( Between current carrying& non-current carrying parts)
b) 1.5KV AC, 50Hz for 1 minute. (between contacts & control circuit)
c) 1KV AC, 50Hz for 1 minute. (between non-continuous relay contacts)
Electrical connectionScrew type terminals with self lifting clamps
Dimension72 x 72 x 84mm (W x H x D)110 x 86 x 68mm (L x W x D)
Enclosure (series)TS- SeriesTS- Series

Hints on correct use:

•While fixing the back cover, care should be taken to ensure correct orientation of the cover w.r.t terminal markings.
•After adjusting the real time clock remove the shorting across the terminals P1 & P2. This facility will prevent the tampering of clock.

Caution:

  • •Do not apply power to P1 & P2 terminals.