M2 Series Annunciator
Model | No. of Windows | Function | Source Voltage | Output | Input | Data Sheet |
Regular M2 Series Annunciator | ||||||
M2-2 | 2 windows | Programmable Fault annunciator | 85-270V AC / DC, 18-90V AC / DC | 2 relays 1 c/o (C-NO), (trip / Alarm) | 2 potential free (Zero Volt) fault input | Click Here |
M2-4 | 4 windows | Programmable Fault annunciator | 85-270V AC / DC, 18-90V AC / DC | 2 relays 1 c/o (C-NO), (trip / Alarm) | 4 potential free (Zero Volts) fault inputs | |
M2-6 | 6 windows | Programmable Fault annunciation | 85-270V AC / DC, 18-90V AC / DC | 2 relays 1 c/o (C-NO), (trip / Alarm) | 6 potential free (Zero Volts) fault inputs | |
M2-8 | 8 windows | Programmable Fault annunciation | 85-270V AC / DC, 18-90V AC / DC | 2 relays 1 c/o (C-NO), (trip / Alarm) | 8 potential free (Zero Volts) fault inputs | |
M2-12 | 12 windows | Programmable Fault annunciator | 85-270V AC / DC | 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) | 12 potential free (Zero Volts) fault inputs | Click Here |
M2-16 | 16 windows | Programmable Fault annunciation | 85-270V AC / DC | 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) | 16 potential free (Zero Volts) fault inputs | |
M2-20 | 20 windows | Programmable Fault annunciation | 85-270V AC / DC | 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) | 20 potential free (Zero Volts) fault inputs | |
M2-24 | 24 windows | Programmable Fault annunciation | 85-270V AC / DC | 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) | 24 potential free (Zero Volts) fault inputs | |
Optional Annunciator | ||||||
M2-1 | 1 windows | Programmable Fault annunciation | 110VAC | 1 c/o (NC-C-NO) | 1 fault input (12V AC / DC – 240VAC / 220V DC) | |
M2-12 | 12 windows | Programmable Fault annunciation | 24V DC | 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) | 12 potential free (Zero Volts) fault inputs | |
M2-16 | 16 windows | Programmable Fault annunciation | 24V DC | 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) | 16 potential free (Zero Volts) fault inputs | |
M2-24 | 24 windows | Programmable Fault annunciator | 24V DC | 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) | 24 potential free (Zero Volts) fault inputs | |
M2-12R | 12 windows | Programmable Fault annunciation | 85-270V AC / DC | 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) | 12 potential free (Zero Volts) fault inputs | |
M2-16R | 16 windows | Programmable Fault annunciator | 85-270V AC / DC | 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) | 12 potential free (Zero Volts) fault inputs | |
M2-24R | 24 windows | Programmable Fault annunciation | 85-270V AC / DC | 2 relays 1 c/o (NC-C-NO), (trip / Alarm), 2 relays 1c/o (C-NO) (Hooter, AC Fail) | 12 potential free (Zero Volts) fault inputs |