SPECIFICATION BASIC

annunciator dealer in kolkata

Product Features:

  • Sleek, light weight, ABS enclosure
  • Super bright, Red color SMD, LED for fault indications
  • Test / Mute / Acknowledge / Reset (buttons in front and terminals at rear) are available.
  • Multiple Specification Basic units terminals can be connected in parallel to achieve more windows
  • Each window can be programmed for fault inputs as NO or NC and output as alarm or trip
  • Above program can be locked by removing the short link across specified terminals
  • Over voltage protection
  • Basic Models: M2-2 / M2-4 / M2-6 / M2-8
  • Advanced Models: M2-12 / M2-16 / M2-24
  • Available in 12, 16 and 24 windows respectively
ModelM2-8M2-6M2-4M2-2
FunctionProgrammable fault annunciator
Rated supply voltage85V to 270V AC/DC / 18V to 90V AC/DC
Rated frequency50 / 60Hz ± 5% (85-270V AC/DC)
Power ConsumptionAC Approx.15VA ,DC Approx.10W(85-270V AC/DC)  AC Approx.10VA ,DC Approx.5W(18-90 V AC/DC)
No. of windows8 windows6 windows4 windows2 windows
Fault input contactsSelectable NO / NC type for every channel (No Volt)
Window colourRed
Control output (No. of relays)2 (Trip and Non-trip (Alarm))
Contact rating1 c/o rated for 5A @ 250V AC / 28V DC, resistive load
Test facilityProvided (operational test)
Cascading facilityProvided
External pushbuttonsProvided
Standard sequenceManual Reset , Auto Reset
Recovery time2sec minimum
Ambient temperatureOperation: -100C to +550C, Storage: -250C to +800C
HumidityMax. 85% RH @ 400C
Service life (under no load)106 operations minimum
Electrical life (under full load)105 operations minimum
Insulation resistance> 100M ohms @ 500V DC
Di-electrical strength1.  2.5KV AC, 50Hz for 1minute. (Between current carrying and non-current carrying parts)

2.  1.5KV AC, 50Hz for 1minute. (Between contacts and control circuit)

3.  750V AC, 50Hz for 1minute. (Between non-continuous contacts of the relay)

Electrical connectionScrew type terminals with self lifting clamps
Window size(L x W)31.5 X 27.5mmTop 2 windows

66  X 27.5mm(LXW)

Bottom 4 windows

31.5 X 27.5mm (LXW)

66  X 27.5mm (LXW)66  X 58mm (LXW)
Dimension (over-all)142.5 x 73.5 x 78mm ( WxHxD)
Enclosure (series)‘N’ series

Connections:

annunciator distributor in kolkata

Dimensions:

annunciator provider in kolkata:

Accessories:

  • Panel locking side anchors -4 Nos

Hints on correct use:

Tools and Fasteners:Kindly use star – type screw driver for tightening the screws.

NOTE: Specification Basic Installation should include a disconnecting device, like switch or circuit breaker, with clear ON/OFF markings, to turn-off the auxiliary supply(control power).The disconnecting device should be within the reach of the equipment and the operator.

Caution:

Specification Basic:

  • Apply appropriate personal protective equipment(PPE) and follow safety work practices
  • Only qualified electrical workers should install this equipment. Such work should be performed only after reading this entire set of instructions.
  • If the equipment is not used in the manner specified by the manufacturer, the protection provided by the equipment may be impaired.
  • NEVER work alone.
  • The successful operation of this equipment depends upon proper handling, installation and operation. Neglecting fundamental installation requirements may lead to personal injury as well as damage to electrical equipment or other property
  • NEVER bypass external fusing.
  • Before performing Dielectric or Megger testing on any equipment in which the device is installed, disconnect all the input and output wires to the device. High voltage testing may damage electronic components contained in the device.
  • The device should be installed in a suitable electrical enclosure.
  • Failure to follow these instructions will result in death or serious injury.